Auxiliary devices Analitpribor GDP, IM, GC, HS, FO, etc.
The GDP-102 generator is designed for the preparation of calibration gas mixtures (PGS) of target components in air (nitrogen).
The sources of the microflow of IM are replaceable elements of thermodiffusion generators of gas mixtures.
The GC-500 oxygen microconcentration generator is used to prepare calibration gas mixtures.
Refrigerators HC-2, HC-3, HC-4, XB-1 are used to separate condensate and heavy hydrocarbons from the gas mixture
Volumetric filters FO-500, FO-O-500 are designed to remove coarse dust (FO-500) and reduce moisture content (FO-O-500) from the gas mixture.
The OP-1 sample desiccant is designed for drying the gas mixture by cooling.
VTR, VZ, BP valves are designed to regulate the analyzed gas medium and overlap gas pipelines.
The gas distributor RGM is designed for alternate sampling of the analyzed gas mixture from four, six or eight sampling points, depending on the design.
The flow stimulators P, PR are designed to ensure the necessary flow of the gas mixture (sample) through the path of the gas analyzer.
The RD-1 pressure regulator is designed to reduce the gas pressure at the outlet with significant fluctuations at the inlet.
The RD-10 pressure reducer is designed to reduce the gas pressure at the outlet with not significant fluctuations at the inlet (10%).
Thermal coolers TX-410 are designed for drying the gas mixture by cooling.
The PC control panel is designed to display and adjust the readings of digital and analog sensors that are part of the SCAPO system and its other elements.
The AI interface adapter is designed to work as part of the SCAPO system.
The control panel is designed for remote control of boiler room operating modes.
The stationary OPTIMA mode optimization device is designed to indicate the oxygen content.
ORGO is designed for the preparation of a mixture of air with natural or liquefied petroleum gases.
Tiara containers are designed for localization, safe evacuation and storage of objects containing dangerous chemicals.
IRR flow control indicators are designed for visual observation of the presence of a gas mixture flow rate (PGS–GSO) of a certain value indicated by a risk, as well as a change in the sample flow rate using a regulator.
Flow stabilizer IBIAL.418314.047 to Ancat-64M3.
The flow stimulator IBIAL.418315.048 is designed for forced sampling. Suitable for working with ANCAT-7664Micro gas analyzers.
All Analitpribor products
About Analitpribor
-
development
Development of gas-analytical equipment, ranging from scientific research to mass production of devices produced on their basis. -
PRODUCTION BASE
Research and development work, individual developments, training in proper operation, installation and maintenance of devices. -
application
Utilities, oil and gas industry, chemical and coal industry, metallurgy and energy, labor protection and safety, etc.
Information Board Analitpribor
- (727)345-47-04
- (3955)60-70-56
- (8182)63-90-72
- (8512)99-46-04
- (3852)73-04-60
- (4722)40-23-64
- (4162)22-76-07
- (4832)59-03-52
- (8352)28-53-07
- (351)202-03-61
- (8202)49-02-64
- (3022)38-34-83
- (395)279-98-46
- (4932)77-34-06
- (3412)26-03-58
- (4012)72-03-81
- (4842)92-23-67
- (843)206-01-48
- (3842)65-04-62
- (4212)92-98-04
- (8332)68-02-04
- (4966)23-41-49
- (4942)77-07-48
- (861)203-40-90
- (391)204-63-61
- (3522)50-90-47
- (4712)77-13-04
- (4742)52-20-81
- (3519)55-03-13
- (375)257-127-884
- (495)268-04-70
- (8152)59-64-93
- (8552)20-53-41
- (831)429-08-12
- (3843)20-46-81
- (383)227-86-73
- (3496)41-32-12
- (3812)21-46-40
- (4862)44-53-42
- (3532)37-68-04
- (8412)22-31-16
- (342)205-81-47
- (8142)55-98-37
- (8112)59-10-37
- (863)308-18-15
- (4912)46-61-64
- (812)309-46-40
- (846)206-03-16
- (8342)22-96-24
- (845)249-38-78
- (8692)22-31-93
- (3652)67-13-56
- (4812)29-41-54
- (862)225-72-31
- (8652)20-65-13
- (3462)77-98-35
- (8212)25-95-17
- (4752)50-40-97
- (998)71-205-18-59
- (8482)63-91-07
- (3822)98-41-53
- (4872)33-79-87
- (4822)63-31-35
- (3452)66-21-18
- (347)229-48-12
- (3012)59-97-51
- (8422)24-23-59
- (8672)28-90-48
- (4922)49-43-18
- (423)249-28-31
- (844)278-03-48
- (8172)26-41-59
- (473)204-51-73
- (4112)23-90-97
- (4852)69-52-93
- (343)384-55-89